<LOGO>
FM Transmitter Measurement Report
Created: 2024-11-01 03-22-29
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.20 MHz 5/5, 0 dBuV RMC
Pilot RDS Phase Difference
0.0 kHz 3.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
3 kHz 70 kHz 17004 0,0118
Modulation Power
Limit Measuring Tolerance
10,0 dBr 3,0 dBr
MIN AVE MAX % above 13,0 dBr
5,3 dBr 6,22 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 2 3:22, 1.11.2024
RT
"RMC BLOIS 107.2 "
AF EON
90.1, 90.2, 93.7, 95.3, 96.5, 96.8, 99.6, 100.7, 101.2, 101.6, 103.1, 103.2, 103.7, 103.9, 107.2, 107.3, 107.5 MHz -
FM Scope Station: 107.20 MHz, signal: 5/5 (56 dBuV) Max at: 70 kHz MIN: 3 kHz % above 75 kHz: 0,0118 Acquired: 2024/11/01 3:21:25 Total samples: 17004 Equivalent time: 0:14:10 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,6 dBr MIN: 5,3 dBr AVE: 6,22 dBr % above 13,0 dBr: 0,0 Last value: 6,3 dBr (2024/11/01 3:21:24) Station: 107.20 MHz, signal: 5/5 (56 dBuV) 03:10 03:12 03:14 03:16 03:18 03:20 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality